00 81L 1122PPPP090 000001 01AUSSCHREIBEN.DE - Triflex English 07.03.22 000002 02AUSSCHREIBEN.DE 000003 08_ Euro 000004 1101 N Lot 000005 12Triflex Towersafe - Tower and foundation 000006 20 000007 26 Triflex Towersafe© 000008 26 Tower and foundation waterproofing system with Triflex 000009 26 Towersafe 000010 26 000011 2611BConstruction project: '...' 000012 2612BArchitect/client: '...' 000013 26 000014 26 Preliminary remarks: 000015 26 000016 26 Work is carried out using products from the Minden- 000017 26 based company Triflex GmbH & Co. KG. 000018 26 000019 26 Compliance with all applicable guidelines is taken into 000020 26 account and required for the different recommended 000021 26 system build-ups using Triflex products. 000022 26 000023 26 The waterproofing systems within the system build-up 000024 26 with Triflex Towersafe are covered by European 000025 26 Technical Approvals (ETAs) issued by the German 000026 26 approval body for non-regulated construction products 000027 26 and types of construction, the Deutsches Institut fr 000028 26 Bautechnik (DIBt), and meet the requirements of the 000029 26 EUlsquo;s Construction Products Directive (CE mark) in 000030 26 accordance with ETAG No. 005 in the highest usage 000031 26 category. This waterproofing system is classified as a 000032 26 rigid roofing structure, among other things, in 000033 26 accordance with German regional building regulations. 000034 26 000035 26 There is a General Building Supervisory Authority Test 000036 26 Certificate (abP) in accordance with the Building 000037 26 Regulations List A, Part 2, No. 1.4 for the system 000038 26 build-up as liquid applied waterproofing, as joint 000039 26 waterproofing for concrete components with high water- 000040 26 penetration resistance and as waterproofing for 000041 26 structures on surfaces at an incline of up to 90ű in 000042 26 accordance with Building Regulations List A, Part 2, 000043 26 No. 2.51. 000044 26 000045 26 Before the contract is awarded, contractors must prove 000046 26 that they have been trained in the application of 000047 26 Triflex products. Otherwise, instruction by a trainer 000048 26 shall be provided on-site. 000049 26 000050 26 The quantities contained herein shall be checked on the 000051 26 building site. 000052 26 000053 26 Billing shall be based on measurements conducted 000054 26 jointly by the contractor and client. 000055 26 000056 26 The waterproofing system must be applied so as to 000057 26 prevent rainwater from penetrating the system structure 000058 26 in the event that work is interrupted. 000059 26 000060 26 For disposal of rubble, the cartage and landfill costs 000061 26 shall be included in the individual prices or itemised 000062 26 separately. 000063 26 000064 26 Concerns about prior work performed by other 000065 26 contractors shall be communicated to the client in 000066 26 writing immediately, ideally before work begins. 000067 26 000068 26 It is recommended that the bidder view the work site 000069 26 prior to submitting a tender. 000070 26 000071 26 If alterations or special work not included herein 000072 26 become necessary after work has commenced, detailed 000073 26 notification shall be given before going ahead with 000074 26 such alterations or special work, and the work shall 000075 26 subsequently be billed separately. 000076 26 000077 26 Unless explicitly stated otherwise, all work shall be 000078 26 regarded as a comprehensive turnkey service, including 000079 26 the supply of all required materials and ancillary 000080 26 services. 000081 26 000082 26 The contract comprises the following components: 000083 26 ú Specifications 000084 26 ú System description and manufacturerlsquo;s product 000085 26 information 000086 26 ú Building code regulations 000087 26 ú Accident prevention regulations 000088 26 ú German Construction Contract Procedures (VOB), Part B 000089 26 in the versions valid at the time of conclusion of the 000090 26 contract. 000091 26 000092 26 The system build-up must be adapted by the expert 000093 26 planner to meet the project-specific requirements. 000094 26 Detailed tender texts must be created by the planner on 000095 26 his or her own authority. There is no specific project 000096 26 consultation associated with the issue of these draft 000097 26 specifications. The preparation of drafts is a non- 000098 26 obligatory service provided by Triflex. Any legal 000099 26 claims from this service are excluded. 000100 26 000101 26 000102 26 Last updated: 03/2017 000103 110101 N Section 000104 12General 000105 2101010001 NNN psch 000106 25Building site preparation 000107 26 Building site preparation 000108 310101 000109 110102 N Section 000110 12Structure and substrate inspection 000111 2101020001 NNN psch 000112 25Cavities 000113 26 Checking for cavities by tapping the existing concrete 000114 26 surfaces with a hammer, and marking and photographing 000115 26 any areas that sound hollow. 000116 26 Disposing of rubble properly. 000117 2101020002 NNN psch X 000118 25Adhesive tensile strength 000119 26 Determining and recording the specified adhesive 000120 26 tensile strength of the existing substrate using a 000121 26 suitable gauge (e.g. a Freundl device). 000122 2611BNumber of measurements: '.........' 000123 2101020003 NNN psch X 000124 25Moisture content 000125 26 Determining and recording the moisture content of the 000126 26 existing concrete substrate using a suitable gauge 000127 26 (e.g. a CM device). 000128 2611BNumber of measurements: '.........' 000129 310102 000130 110103 N Section 000131 12Substrate pre-treatment 000132 20 000133 26 (See Triflex Towersafe system description, Substrate 000134 26 pre-treatment table). 000135 2101030001 NNN mę 000136 25Milling 000137 26 Removing any contaminated surfaces on the concrete with 000138 26 a suitable milling machine approx. 3-5 mm in depth in 000139 26 order to ensure the adhesive property and soundness of 000140 26 the substrate; incl. acknowledgement of delivery, off- 000141 26 site transportation and proper disposal of the milled 000142 26 material. 000143 2101030002 NNN mę 000144 25Grinding 000145 26 Preparing the substrate in accordance with the system 000146 26 description, Substrate pre-treatment table, by grinding 000147 26 with suitable abrasive tools, incl. cleaning, 000148 26 acknowledgement of delivery, off-site transportation 000149 26 and proper disposal of any rubble. 000150 2101030003 NNN m 000151 25Grinding the junctions 000152 26 Preparing the mineral substrates, wall junctions and 000153 26 details by grinding with suitable abrasive tools, incl. 000154 26 cleaning, acknowledgement of delivery, off-site 000155 26 transportation and proper disposal of any rubble. 000156 2101030004 NNN mę 000157 25Preparing metal substrates 000158 26 Thorough cleaning of metal substrates and abrasion or 000159 26 degreasing with Triflex Cleaner. 000160 2101030005 NNN mę 000161 25Preparing the tower flange 000162 26 Cleaning the upright surfaces of the tower flange and 000163 26 abrasion or degreasing of at least 15 cm with Triflex 000164 26 Cleaner. 000165 310103 000166 110104 N Section 000167 12Triflex Primer 000168 20 000169 26 See Triflex Towersafe system description, Substrate pre 000170 26 -treatment table. 000171 2101040001 NNN mę X 000172 25Priming the concrete 000173 26 Priming the concrete substrate with Triflex Towersafe 000174 26 Primer. 000175 2611BJunction height: '.........' cm, 000176 2612Bwidth: '.........' cm 000177 26 Volume: at least 0.40 kg/mę 000178 26 Application according to the material 000179 26 manufacturerlsquo;s technical guidelines. Adhesion to 000180 26 the substrate must be checked on a case-by-case basis. 000181 2101040002 NNN mę X 000182 25Priming the metal 000183 26 Priming the metal substrate with Triflex Metal Primer 000184 26 (spray can). 000185 2611BJunction height: '.........' cm, 000186 2612Bwidth: '.........' cm 000187 26 Volume: approx. 0.10 l/mę 000188 26 Application according to the material 000189 26 manufacturerlsquo;s technical guidelines. 000190 310104 000191 110105 N Section 000192 12Triflex repairs 000193 2101050001 NNN mę X 000194 25Repair mortar, mineral substrate (Rt>10 mm) 000195 26 Repairing defective spots on the existing mineral 000196 26 substrate with Triflex Cryl RS 240 repair mortar in the 000197 26 area of roughness depths Rt >10 mm. 000198 26 Triflex Cryl RS 240, colour 7023, volume: at least 2.20 000199 26 kg/mę per mm of layer thickness 000200 2611BAverage layer thickness: '.........' 000201 26 Application according to the material 000202 26 manufacturerlsquo;s technical guidelines. 000203 310105 000204 110106 N Section 000205 12Triflex uncoupling 000206 2101060001 NNN m 000207 25Sealing off tower from foundation 000208 26 Sealing off the tower from the foundation using joint 000209 26 sealant and Triflex duct tape to raise the free 000210 26 expansion section. 000211 310106 000212 110107 N Section 000213 12Triflex detail waterproofing 000214 20 000215 26 Creating detail waterproofing with Triflex Towersafe 000216 26 incl. Triflex Special Fleece. 000217 26 The Triflex Towersafe waterproofing system has obtained 000218 26 European Technical Approval (ETAG No. 05/0205) with CE 000219 26 mark in the highest usage categories W3, M and S, P1 to 000220 26 P4, S1 to S4, TL4, TH4, BROOF (t1), BROOF (t2), BROOF 000221 26 (t3), and its root resistance is also certified 000222 26 according to FLL standards. 000223 2101070001 NNN m X 000224 25Wall junction 000225 26 Waterproofing the wall junction with Triflex Towersafe 000226 26 incl. Triflex Special Fleece. 000227 26 Volume: at least 3.00 kg/mę 000228 2611BTriflex Special Fleece strip width: '.........' cm. 000229 26 Application according to the material 000230 26 manufacturerlsquo;s technical guidelines. 000231 26 (See Triflex system drawing Towersafe-7101 and 000232 26 Towersafe 7102) 000233 2101070002 NNN Stk 000234 25Waterproofing hard-to-reach details 000235 26 Waterproofing with Triflex ProFibre. 000236 26 Please note: In areas where DIN 18531/the Flat Roof 000237 26 Guidelines are valid, Triflex ProFibre is classified as 000238 26 a special structure to be agreed upon with the client. 000239 26 Application according to the material 000240 26 manufacturerlsquo;s technical guidelines. 000241 2101070003 NNN m X 000242 25Tower segment flange 000243 26 Waterproofing the tower segment flange with Triflex 000244 26 Towersafe incl. Triflex Special Fleece SK. 000245 26 Volume of Triflex Towersafe: at least 3.00 kg/mę 000246 2611BTriflex Special Fleece SK width: '.........' cm. 000247 26 Application according to the material 000248 26 manufacturerlsquo;s technical guidelines. 000249 26 (See Triflex system drawing Towersafe-7103 and 000250 26 Towersafe-7104) 000251 310107 000252 110108 N Section 000253 12Triflex surface waterproofing 000254 2101080001 NNN mę X 000255 25Surface waterproofing 000256 26 Waterproofing the surface with Triflex Towersafe incl. 000257 26 Triflex Special Fleece. 000258 26 Volume of Triflex Towersafe: at least 3.00 kg/mę. 000259 2611BTriflex Special Fleece strip width: '.........' cm. 000260 26 Application according to the material 000261 26 manufacturerlsquo;s technical guidelines. 000262 310108 000263 110109 N Section 000264 12Triflex wearing layer and finish 000265 2101090001 NNN mę X 000266 25Surface "standard" 000267 26 Creating a non-slip surface that can withstand 000268 26 mechanical loads. 000269 26 Coating the surface with Triflex Towersafe, incl. 000270 26 dressing with a surplus of quartz sand, size 0.7-1.2 000271 26 mm. Removing any surplus after curing. Finishing the 000272 26 surface with Triflex Towersafe Finish. 000273 2611BColour: '.........' at the discretion of the client. 000274 26 Volume of Triflex Towersafe: at least 1.00 kg/mę. 000275 26 Volume of quartz sand (0.7-1.2 mm): at least 7.00 kg/mę 000276 26 with a surplus. 000277 26 Volume of Triflex Towersafe Finish: at least 0.70 000278 26 kg/mę. 000279 26 Application according to the material 000280 26 manufacturerlsquo;s technical guidelines. 000281 2101090002 NNN mę X 000282 25"Smooth surface" version 000283 26 Creating a surface that can withstand mechanical loads. 000284 26 Coating the surface with Triflex Towersafe and 000285 26 finishing the surface with Triflex Towersafe Finish. 000286 2611BColour: '.........' at the discretion of the client. 000287 26 Volume of Triflex Towersafe: at least 1.00 kg/mę. 000288 26 Volume of Triflex Towersafe Finish: at least 0.50 000289 26 kg/mę. 000290 26 Application according to the material 000291 26 manufacturerlsquo;s technical guidelines. 000292 310109 000293 110110 N Section 000294 12Hourly rates 000295 2101100001 NNN h 000296 25Foreman 000297 26 Hourly rate of a foreman. 000298 2101100002 NNN h 000299 25Skilled trade worker 000300 26 Hourly rate of a skilled trade worker. 000301 2101100003 NNN h 000302 25Assistant 000303 26 Hourly rate of an assistant. 000304 310110 000305 110111 N Section 000306 12Materials 000307 2101110001 NNN kg 000308 25Materials 000309 26 Material consumption upon proof. 000310 310111 000311 110112 N Section 000312 12Disposal 000313 2101120001 NNN psch 000314 25Disposal 000315 26 Disposal of all waste and hazardous waste materials in 000316 26 accordance with the current applicable laws and 000317 26 implementing regulations. 000318 310112 000319 3101 000320 99 00024000321